{"id":862,"date":"2026-08-24T10:00:54","date_gmt":"2026-08-24T10:00:54","guid":{"rendered":"http:\/\/localhost\/sito_calref\/?page_id=862"},"modified":"2026-08-27T13:51:48","modified_gmt":"2026-08-27T12:51:48","slug":"services-accredites-disponibles","status":"publish","type":"page","link":"https:\/\/www.calref.it\/fr\/servizi_2\/servizi-accreditati\/servizi-accreditati-disponibili\/","title":{"rendered":"Services accr\u00e9dit\u00e9s (Euramet CG-17)"},"content":{"rendered":"<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"827\" height=\"768\" src=\"http:\/\/localhost\/sito_calref\/wp-content\/uploads\/2026\/08\/new_logo_CG17C.png\" alt=\"\" class=\"wp-image-865\" srcset=\"https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17C.png 827w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17C-300x279.png 300w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17C-150x139.png 150w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17C-768x713.png 768w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17C-350x325.png 350w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Certificat de calibration LAT pour les instruments de pression avec incertitude nominale \u00e9tendue<\/strong> <strong><em>U<\/em>&nbsp;&lt; 0,05% FS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Calibrage \u201c Complet \u201d conform\u00e9ment \u00e0 la ligne directrice Euramet CG N0. 17 Ver. 4.1<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette proc\u00e9dure de calibration est la plus compl\u00e8te parmi celles disponibles selon la ligne directrice allemande et permet d\u2019\u00e9valuer de la mani\u00e8re la plus efficace les caract\u00e9ristiques m\u00e9trologiques de l\u2019instrument en cours de calibration. Sa complexit\u00e9 en fait une proc\u00e9dure inappropri\u00e9e pour la calibration d\u2019instruments moins pr\u00e9cis. Elle est g\u00e9n\u00e9ralement utilis\u00e9e lors de comparaisons exp\u00e9rimentales inter-laboratoires ou intra-laboratoires ou pour garantir la reproductibilit\u00e9 de la mesure des \u00e9chantillons de travail d\u2019un centre de calibration.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;11 points de pression<\/li>\n\n\n\n<li>3 cycles de mesure<\/li>\n\n\n\n<li>ascension et descente<\/li>\n\n\n\n<li>66 points au total entre les deux<\/li>\n\n\n\n<li>identification de l\u2019erreur et de l\u2019incertitude de mesure \u00e9tendue pour chaque point de mesure (6)<\/li>\n\n\n\n<li>d\u00e9termination de l\u2019incertitude \u00e9tendue dans le cas o\u00f9 les corrections ne sont pas effectu\u00e9es<\/li>\n\n\n\n<li>d\u00e9termination de l\u2019incertitude maximale de mesure sur toute la plage de mesure<\/li>\n\n\n\n<li>d\u00e9termination de l'incertitude maximale \u00e9tendue sur toute la plage de mesure, dans le cas o\u00f9 les corrections ne sont pas effectu\u00e9es<\/li>\n\n\n\n<li>graphique des erreurs et des incertitudes associ\u00e9es<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"827\" height=\"768\" src=\"http:\/\/localhost\/sito_calref\/wp-content\/uploads\/2026\/08\/new_logo_CG17S.png\" alt=\"\" class=\"wp-image-866\" srcset=\"https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17S.png 827w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17S-300x279.png 300w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17S-150x139.png 150w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17S-768x713.png 768w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17S-350x325.png 350w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Certificat de calibration LAT pour les instruments de pression avec incertitude nominale \u00e9tendue<\/strong> <strong>0,05% FS \u2264&nbsp;<em>U<\/em>&nbsp;&lt; 0,2% FS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Calibrage \u201c Standard \u201d conform\u00e9ment \u00e0 la directive Euramet CG N0. 17 Ver. 4.1<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette proc\u00e9dure de calibration est adapt\u00e9e aux instruments de moyenne qualit\u00e9 m\u00e9trologique. M\u00eame si elle est moins compl\u00e8te que la \u201c Comprehensive \u201d, sa complexit\u00e9 la rend inapte \u00e0 la calibration d\u2019instruments moins pr\u00e9cis. Si l\u2019incertitude calcul\u00e9e \u00e9tait inf\u00e9rieure \u00e0 0,050% FS, son valeur serait forc\u00e9e \u00e0 0,050% FS.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;11 points de pression<\/li>\n\n\n\n<li>1 cycle complet<\/li>\n\n\n\n<li>2 cycles de mont\u00e9e de 4 points \u00e0 environ 10%FS 30%FS, 60%FS et 90%FS.<\/li>\n\n\n\n<li>30 points au total lors des confrontations<\/li>\n\n\n\n<li>identification de l\u2019erreur et de l\u2019incertitude de mesure \u00e9tendue pour chaque point de mesure (6)<\/li>\n\n\n\n<li>d\u00e9termination de l\u2019incertitude \u00e9tendue dans le cas o\u00f9 les corrections ne sont pas effectu\u00e9es<\/li>\n\n\n\n<li>d\u00e9termination de l\u2019incertitude maximale de mesure sur toute la plage de mesure<\/li>\n\n\n\n<li>d\u00e9termination de l'incertitude maximale \u00e9tendue sur toute la plage de mesure, dans le cas o\u00f9 les corrections ne sont pas effectu\u00e9es<\/li>\n\n\n\n<li>graphique des erreurs et des incertitudes associ\u00e9es<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"827\" height=\"768\" src=\"http:\/\/localhost\/sito_calref\/wp-content\/uploads\/2026\/08\/new_logo_CG17B.png\" alt=\"\" class=\"wp-image-864\" srcset=\"https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17B.png 827w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17B-300x279.png 300w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17B-150x139.png 150w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17B-768x713.png 768w, https:\/\/www.calref.it\/wp-content\/uploads\/2026\/08\/new_logo_CG17B-350x325.png 350w\" sizes=\"auto, (max-width: 767px) 89vw, (max-width: 1000px) 54vw, (max-width: 1071px) 543px, 580px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Certificat de calibration LAT pour les instruments de pression avec incertitude nominale \u00e9tendue<\/strong> <strong><em>U<\/em>&nbsp;\u2265 0,2% FS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Calibrage \u201c Basic \u201d conform\u00e9ment \u00e0 la ligne directrice Euramet CG N0. 17 Ver. 4.1<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette proc\u00e9dure de r\u00e9glage est la plus simple parmi celles recommand\u00e9es par la ligne de r\u00e9f\u00e9rence. Elle est utilis\u00e9e pour le r\u00e9glage d\u2019instruments peu pr\u00e9cis qui ne n\u00e9cessitent pas d\u2019\u00e9valuations particuli\u00e8rement d\u00e9taill\u00e9es de leurs caract\u00e9ristiques m\u00e9trologiques. En g\u00e9n\u00e9ral, la r\u00e9solution de ces instruments joue un r\u00f4le crucial dans la composition de l\u2019incertitude de mesure. Si l\u2019incertitude calcul\u00e9e est inf\u00e9rieure \u00e0 0,20% FS, sa valeur serait forc\u00e9e \u00e0 0,20% FS.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>6 points de pression<\/li>\n\n\n\n<li>un cycle complet<\/li>\n\n\n\n<li>Deux cycles de mont\u00e9e de 2 points environ<\/li>\n\n\n\n<li>0% FS et 50% FS<\/li>\n\n\n\n<li>16 points au total en comparaison<\/li>\n\n\n\n<li>identification de l\u2019erreur et de l\u2019incertitude de mesure \u00e9tendue pour chaque point de mesure (6)<\/li>\n\n\n\n<li>d\u00e9termination de l\u2019incertitude \u00e9tendue dans le cas o\u00f9 les corrections ne sont pas effectu\u00e9es<\/li>\n\n\n\n<li>d\u00e9termination de l\u2019incertitude maximale de mesure sur toute la plage de mesure<\/li>\n\n\n\n<li>d\u00e9termination de l'incertitude maximale \u00e9tendue sur toute la plage de mesure, dans le cas o\u00f9 les corrections ne sont pas effectu\u00e9es<\/li>\n\n\n\n<li>graphique des erreurs et des incertitudes associ\u00e9es<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">Autres services disponibles :<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.riferibilita.it\/servizi_2\/servizi-accreditati\/servizi-accreditati-dkd-r-6-1\/\">Services selon DKD-R 6-1<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.riferibilita.it\/servizi_2\/servizi-accreditati\/servizi-accreditati-metodo-interno\/\">Services selon le M\u00e9thode compl\u00e8te<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.riferibilita.it\/servizi_2\/servizi-accreditati\/dichiarazione-di-conformita\/\">D\u00e9claration de conformit\u00e9<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Certificato di taratura LAT per strumenti di pressione con Incertezza estesa nominale U&nbsp;&lt; 0,05% FS Taratura \u201cComprehensive\u201d secondo la linea guida Euramet CG N0. 17 Ver. 4.1 Questa procedura di taratura \u00e8 la pi\u00f9 completa tra quelle disponibili e permette di valutare nel modo pi\u00f9 efficace le caratteristiche metrologiche dello strumento in taratura. La sua &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/www.calref.it\/fr\/servizi_2\/servizi-accreditati\/servizi-accreditati-disponibili\/\" class=\"more-link\">Continuez \u00e0 lire<span class=\"screen-reader-text\"> &#8220;Servizi accreditati (Euramet CG-17)&#8221;<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":843,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-862","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/pages\/862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/comments?post=862"}],"version-history":[{"count":11,"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/pages\/862\/revisions"}],"predecessor-version":[{"id":1004,"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/pages\/862\/revisions\/1004"}],"up":[{"embeddable":true,"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/pages\/843"}],"wp:attachment":[{"href":"https:\/\/www.calref.it\/fr\/wp-json\/wp\/v2\/media?parent=862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}